General
Make sure you have enough room in your designated server rack for a 1U sized server and at least one
free power outlet.
A second power outlet is recommended as the server has two redundant power supplies.
More outlets may be required according to the server configuration that is explained in this document.
Network & Firewall
Visonic recommends connecting the PowerManage behind a firewall or a NAT device and using a
restrictive policy for access; the PowerManage server is not secured against Internet attacks.
For support purposes, it is recommended to allow access from Visonic's address range 91.207.90.0/23.
Allocation of 1 fixed public IP address.
DNS hostname with A and PTR records for the allocated IP address, this should be done by
whoever is in charge of your domain whether it's your IT department, your ISP or an online DNS
registrar.
A symmetric uplink connection of 1 Mbit is required at all times
No blocking of outgoing server connections to the Internet
The server receives control panel events via TCP and UDP ports 5001 and 8080; these must be
accessible from the Internet.
The web management interface of the PowerManage server can be reached by port 80.
The back-end management interface is accessible on port 22 (SSH).