D-304046 TOWER-20 PG2 Installation Instructions 3
2.2 Battery Insertion
It is recommended to perform the first batteries insertion on a flat surface (see Figure 4). After battery insertion, the LED will flash for 60
seconds and then the detector will enter a 15 minutes' local diagnostic mode.
A. Tamper switch B. Press firmly to release the bracket C. 3 screws
Figure 4 – Battery Insertion
2.3. Enrollment
Refer to the PowerMaster control panel's Installer Guide and follow the procedure under the "02:ZONES/DEVICES" option of the Installer Menu.
A general description of the procedure is provided in the following flow chart.
Step 1 Step 2 Step 3 Step 4
Enter the Installer menu and select
“02:ZONES/DEVICES”
Select "ADD NEW DEVICE"
See Note 1
Enroll the device (see Figure 5) or
enter the device ID
Select a detector number for
the new flood detector
Step 5 Step 6 Step 7
Configure Location, Zone Type &
Chime parameters
Enter PARTITIONS.
See Note 2
Assign partitions to the detector by
pressing the
,
and/or
buttons on the
panel
means scroll and select
Notes:
[1] If the detector is already enrolled you can configure the detector parameters and assign partitions via the “Modify Devices” option – see
Step 2.
[2] PARTITIONS will appear only if PARTITIONING was previously enabled in a panel that supports the Partitioning feature (for further details,
see "Partitioning" in the PowerMaster Installer Guide).
Z14.SET CHIME
Z14.ZONE TYPE
MODIFY DEVICES
Z14.LOCATION Z14.PARTITIONS Z14:P1 P2 P3
ID No. 130-XXXX
Z14:Motion Sens
ENTR ID:XXX-XXXX
ENROLL NOW or ADD NEW DEVICES
02:ZONES/DEVICES