Visonic POWERMASTER-10 - INSTALLER GUIDE Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Systemy kontroli dostępu bezpieczeństwa Visonic POWERMASTER-10 - INSTALLER GUIDE. Visonic POWERMASTER-10 - INSTALLER GUIDE Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 82
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
www.visonic.com
PowerMaster-10 G2
INSTALLER GUIDE
Fully supervised wireless alarm control system
Przeglądanie stron 0
1 2 3 4 5 6 ... 81 82

Podsumowanie treści

Strona 1 - INSTALLER GUIDE

www.visonic.comPowerMaster-10 G2INSTALLER GUIDEFully supervised wireless alarm control system

Strona 2 - Installer's Guide

3. POWERMASTER-10 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 9 3.2 Connecting to the Telephone Line PHONE WIRING Connect th

Strona 3

3. POWERMASTER-10 G2 INSTALLATION 10 D-303222 PowerMaster-10/30 G2 Installer's Guide 3.3 System Planning & Programming Program the system no

Strona 4 - 1. INTRODUCTION

3. POWERMASTER-10 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 11 3.5 PGM-5 Installation PGM-5 is an output interface module

Strona 5

3. POWERMASTER-10 G2 INSTALLATION 12 D-303222 PowerMaster-10/30 G2 Installer's Guide 3.6 Adding Wired Zones or PGM Device Required tools: Cutter

Strona 6

3. POWERMASTER-10 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 13 PGM AND ZONE WIRING A. PGM output Vmax=30v Imax=100mA B

Strona 7

3. POWERMASTER-10 G2 INSTALLATION 14 D-303222 PowerMaster-10/30 G2 Installer's Guide Notes for UL installations: 1. A device that is connected

Strona 8

3. POWERMASTER-10 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 15 CONNECTING AC POWER USING INTERNAL AC/DC POWER SUPPLY UNIT

Strona 9

3. POWERMASTER-10 G2 INSTALLATION 16 D-303222 PowerMaster-10/30 G2 Installer's Guide 3.8 Supplying Power to the Unit Connect power to the Power

Strona 10 - Figure 3.2 –Phone Wiring

4. POWERMASTER-30 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 17 4. POWERMASTER-30 G2 INSTALLATION Required tool: Philips s

Strona 11 - 3.4 GSM Module Installation

4. POWERMASTER-30 G2 INSTALLATION 18 D-303222 PowerMaster-10/30 G2 Installer's Guide 4.2 Opening the PowerMaster-30 G2 Control Panel and Bracke

Strona 12 - 3.5 PGM-5 Installation

D-303222 PowerMaster-10/30 G2 Installer's Guide 1 PowerMaster-10/30 G2 Version 16 Installer's Guide Table of Contents 1. INTRODUCTION ...

Strona 13 - Figure 3.6a – Cable Wiring

4. POWERMASTER-30 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 19 PHONE WIRING IN NORTH AMERICA A. LINE B. SET C. RJ-31X

Strona 14

4. POWERMASTER-30 G2 INSTALLATION 20 D-303222 PowerMaster-10/30 G2 Installer's Guide 4.6 GSM Module Installation (detail "N" in Figur

Strona 15 - Connection

4. POWERMASTER-30 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 21 1. To install the DUAL RS-232 module into the control pane

Strona 16

4. POWERMASTER-30 G2 INSTALLATION 22 D-303222 PowerMaster-10/30 G2 Installer's Guide A. PowerMaster-30 G2 connector B. Front unit C. PGM-5

Strona 17 - Figure 3.9 - Final Closure

4. POWERMASTER-30 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 23 OPTIONAL EXPANDER MODULE, ZONES, SIRENS, AUDIO BOX AND WIRE

Strona 18

4. POWERMASTER-30 G2 INSTALLATION 24 D-303222 PowerMaster-10/30 G2 Installer's Guide The 12V and "GND" terminals can be connected to a

Strona 19 - Figure 4.3a – Phone Wiring

4. POWERMASTER-30 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 25 EXTERNAL POWER CONNECTION Connect the power adaptor to the

Strona 20

4. POWERMASTER-30 G2 INSTALLATION 26 D-303222 PowerMaster-10/30 G2 Installer's Guide 4.13 Closing the PowerMaster-30 G2 Control Panel Control p

Strona 21 - Figure 4.6

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 27 5. PROGRAMMING 5.1 General Guidance This chapter explains the Installer progra

Strona 22

5. PROGRAMMING 28 D-303222 PowerMaster-10/30 G2 Installer's Guide To enter the "Installer Mode" and select an Installer Menu Option pr

Strona 23 - Figure 4.9a –Expander Module

2 D-303222 PowerMaster-10/30 G2 Installer's Guide 5.6.1 General Guidance – "Communication" Flow-Chart & Menu Options ...

Strona 24 - and Siren Wiring

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 29 [3] The system exits the “INSTALLER MODE" menu and returns to the normal

Strona 25

5. PROGRAMMING 30 D-303222 PowerMaster-10/30 G2 Installer's Guide (b) i) Change the Installer Code to a temporary code, ii) exit the Instal

Strona 26 - 4.11 Battery Insertion

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 31 [3] The display shows the device details and the first available free Zone num

Strona 27 - Figure 4.13

5. PROGRAMMING 32 D-303222 PowerMaster-10/30 G2 Installer's Guide   - Configuring New Devices Location (name) setting: [1] To review

Strona 28 - 5. PROGRAMMING

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 33 Zone Type List No. Zone Type Description 1. Exit/Entry 1 This Zone starts th

Strona 29 - 5.2.2 Selecting options

5. PROGRAMMING 34 D-303222 PowerMaster-10/30 G2 Installer's Guide 5.4.3 Deleting a Device Step 1  Step 2  Step 3  Step 4  Step 5 Select &quo

Strona 30 -  or

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 35 To Replace, a device proceed as follows: Step 1  Step 2  Step 3  Step 4  S

Strona 31 - 5.4 Zones / Devices

5. PROGRAMMING 36 D-303222 PowerMaster-10/30 G2 Installer's Guide 5.4.7 Updating Devices after Exiting Installer Mode When exiting the "In

Strona 32 - Part B - Configuration

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 37 5.5.8 91:USER PERMIT 92:BATTERY TYPE 5.5.2 Configuring Ar

Strona 33 - - Configuring New Devices

5. PROGRAMMING 38 D-303222 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions 07:LATCHKEY ARM When "ON", a “la

Strona 34

1. INTRODUCTION D-303222 PowerMaster-10/30 G2 Installer's Guide 3 1. INTRODUCTION PowerMaster-10 G2 and PowerMaster-30 G2 are PowerG-enabled p

Strona 35 - 5.4.5 Replacing a Device

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 39 Option Configuration Instructions 3. CP-01 was tested and certified by ETL/Int

Strona 36

5. PROGRAMMING 40 D-303222 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions disarms the system within the delay time, th

Strona 37 - 5.5 Control Panel

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 41 45:STROBE TIME Define the length of time the strobe light will flash upon alar

Strona 38

5. PROGRAMMING 42 D-303222 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions 56:SCREEN SAVER With Partition disabled The

Strona 39 - SMS REPORT

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 43 "SUPERVISION" Options: after 1/2/4/8/12 (default) hour(s); and disab

Strona 40

5. PROGRAMMING 44 D-303222 PowerMaster-10/30 G2 Installer's Guide 5:MOTION CAMERA Contains configurable features and parameters related to Motio

Strona 41

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 45 5.6.2 Configuring PSTN (landline phone) Connection The PowerMaster panels incl

Strona 42

5. PROGRAMMING 46 D-303222 PowerMaster-10/30 G2 Installer's Guide SIM PIN CODE Enter the PIN code of the SIM card installed in the GSM module

Strona 43

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 47 5.6.4 Configuring Events Reporting to Monitoring Stations The PowerMaster con

Strona 44 - 5.6 Communication

5. PROGRAMMING 48 D-303222 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions Entering Hexadecimal Digits Digit 0…..9 A

Strona 45

1. INTRODUCTION 4 D-303222 PowerMaster-10/30 G2 Installer's Guide Device Configuration Device parameters and related system behavior can be conf

Strona 46

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 49 Option Configuration Instructions Note: For UL installations, the communicatio

Strona 47 - String Editor Functionality

5. PROGRAMMING 50 D-303222 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions Voice <- -> C.S. Ringback time Ambi

Strona 48

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 51 5.6.5 Configuring Events Reporting to Private Users The PowerMaster system can

Strona 49

5. PROGRAMMING 52 D-303222 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions VIEW TIME WINDOW “VIEW TIME WINDOW” menu app

Strona 50

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 53 Option Configuration Instructions UL/DL modes Define whether the downloading

Strona 51 - Ambient level

5. PROGRAMMING 54 D-303222 PowerMaster-10/30 G2 Installer's Guide 5.7.5 PGM Output Configuration Option Configuration Instructions PGM: BY

Strona 52

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 55 Option Configuration Instructions CUST. ZONES NAME TEXT LOC. #05 1 TEXT

Strona 53 - Inst. UL/DL code

5. PROGRAMMING 56 D-303222 PowerMaster-10/30 G2 Installer's Guide 5.8.3 Voice Box Mode1 This mode allows you to determine whether two-way

Strona 54 - 5.7 PGM Output

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 57 Option Instructions TEST ALL DEVICES You can test all devices automatically, o

Strona 55 -  Zone C Z:_ _

5. PROGRAMMING 58 D-303222 PowerMaster-10/30 G2 Installer's Guide The following table presents the test result messages Message Description Unit

Strona 56 - 5.8.2 Record Speech

1. INTRODUCTION D-303222 PowerMaster-10/30 G2 Installer's Guide 5 Wired zones and programmable outputs (PGM) The control panel can support wired

Strona 57

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 59 5.13 Start UL/DL Note: This option is only used during the installation of pa

Strona 58 - 5.9.3 Testing the GSM module

5. PROGRAMMING 60 D-303222 PowerMaster-10/30 G2 Installer's Guide 5.15.2 Select between EN-50131, DD243 and BS8243 To select the desired operati

Strona 59 - 5.12 Serial Number

5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 61 Option Configuration Instructions 06:CONFIRM PANIC A confirmed panic alarm i

Strona 60 - 5.15 Operation Mode

6. PERIODIC TEST 62 D-303222 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions 04:FOB/KP PANIC Define the devices that

Strona 61 - 5.15.3 BS8243 Setup

6. PERIODIC TEST D-303222 PowerMaster-10/30 G2 Installer's Guide 63 6.2 Conducting a Periodic Test The PowerMaster enables you to conduct the p

Strona 62 - 5.15.4 DD243 Setup

6. PERIODIC TEST 64 D-303222 PowerMaster-10/30 G2 Installer's Guide Option Instructions 1. Press to view details of the next untested device.

Strona 63 - 6. PERIODIC TEST

7. MAINTENANCE D-303222 PowerMaster-10/30 G2 Installer's Guide 65 Option Instructions 3. Press continuously to navigate to a different zone

Strona 64

7. MAINTENANCE 66 D-303222 PowerMaster-10/30 G2 Installer's Guide Fault What it means Solution JAMMING A radio-frequency signal which is blockin

Strona 65 -  <location>

8. READING THE EVENT LOG D-303222 PowerMaster-10/30 G2 Installer's Guide 67 7.6 Annual System Check Note: The PowerMaster system must be checked

Strona 66 - 7. MAINTENANCE

APPENDIX A. Specifications 68 D-303222 PowerMaster-10/30 G2 Installer's Guide APPENDIX A. Specifications A1. Functional PowerMaster-10 G2 Power

Strona 67 - 7.4 Fuse Replacement

1. INTRODUCTION 6 D-303222 PowerMaster-10/30 G2 Installer's Guide System Architecture: Security Detectors and Transmitters Main Control Pan

Strona 68 - 8. READING THE EVENT LOG

APPENDIX A. Specifications D-303222 PowerMaster-10/30 G2 Installer's Guide 69 PowerMaster-10 G2 PowerMaster-30 G2 Real Time Clock (RTC) The con

Strona 69 - APPENDIX A. Specifications

APPENDIX A. Specifications 70 D-303222 PowerMaster-10/30 G2 Installer's Guide PowerMaster-10 G2 PowerMaster-30 G2 by GP or equivalent. 4. 9.6V

Strona 70 - A3. Electrical

APPENDIX B. Working with Partitions D-303222 PowerMaster-10/30 G2 Installer's Guide 71 Range Humidity 93% relative humidity, @ 30°C (86°F) 93% r

Strona 71 - A5. Physical Properties

APPENDIX C. Detector Deployment & Transmitter Assignments 72 D-303222 PowerMaster-10/30 G2 Installer's Guide B2. Common Areas Common areas a

Strona 72 - (optional)

APPENDIX C. Detector Deployment & Transmitter Assignments D-303222 PowerMaster-10/30 G2 Installer's Guide 73 Zone Zone Type Location Chime (

Strona 73 - Assignments

APPENDIX D. Event Codes 74 D-303222 PowerMaster-10/30 G2 Installer's Guide C2. Keyfob Transmitter List Transmitter Data AUX button Assignments N

Strona 74

APPENDIX D. Event Codes D-303222 PowerMaster-10/30 G2 Installer's Guide 75 120 Panic 373 Fire detector trouble 121 Duress 380 Sensor trouble 1

Strona 75 - APPENDIX D. Event Codes

APPENDIX E. Sabbath Mode 76 D-303222 PowerMaster-10/30 G2 Installer's Guide D3. Understanding the Scancom Reporting Protocol Data Format The SCA

Strona 76 - D2. SIA Event Codes

APPENDIX F. Glossary D-303222 PowerMaster-10/30 G2 Installer's Guide 77 Wiring Setup A. MC-302E device B. Wired magnetic contact C. Fixed frame

Strona 77 - APPENDIX E. Sabbath Mode

APPENDIX F. Glossary 78 D-303222 PowerMaster-10/30 G2 Installer's Guide Disarming: The opposite of arming - an action that restores the control

Strona 78 - APPENDIX F. Glossary

2. CHOOSING THE INSTALLATION LOCATION D-303222 PowerMaster-10/30 G2 Installer's Guide 7 2. CHOOSING THE INSTALLATION LOCATION To ensure the best

Strona 79

APPENDIX G. Compliance with Standards D-303222 PowerMaster-10/30 G2 Installer's Guide 79 APPENDIX G. Compliance with Standards Compliance with S

Strona 80 - Standards

APPENDIX G. Compliance with Standards 80 D-303222 PowerMaster-10/30 G2 Installer's Guide WARRANTY Visonic Limited (the “Manufacturer") wa

Strona 81 - WARRANTY

© 2013 Visonic Ltd. All rights reserved. PowerMaster-10 / PowerMaster-30 English Installer Guide D-303222www.visonic.comFully supervised wireless alar

Strona 82 - PowerMaster-30 G2

3. POWERMASTER-10 G2 INSTALLATION 8 D-303222 PowerMaster-10/30 G2 Installer's Guide 3. POWERMASTER-10 G2 INSTALLATION Required tool: Philips scr

Komentarze do niniejszej Instrukcji

Brak uwag