MENUS AND FUNCTIONS
20 D-303223 PowerMaster-10/30 G2 User's Guide
(see above) until the display reads [<OK> TO EXIT], or preferably, press
once which brings you immediately to the exit screen [<OK> TO EXIT].
When the display reads [<OK> TO EXIT], press
The system exits the [USER SETTINGS] menu and returns to the normal disarm
state while showing the READY display.
A.3 Buttons used for Navigation & Setting
The keypad's buttons are used for various functions when programming. The following table provides a detailed
description of the function or use of each button.
Navigation / Setting Function
Use to move / scroll forward to the next menu options.
Use to move / scroll backward to the previous menu options.
Use to select a menu option or to confirm a setting or action.
Use to move one level up in the menu or to return to previous setting step.
Use to jump back to the [<OK> TO EXIT] screen to quit programming.
Use to cancel, delete, clear or erase setting, data, etc.
Numerical keypad used to enter numerical data.
B.1 Setting the Zone Bypass Scheme
Bypassing permits arming only part of the system while allowing free movement of people within certain zones
when the system is armed. It is also used to temporarily remove from service faulty zones that require repair
work or to deactivate a sensor if, for example, you are decorating a room.
Here you can set the Zone Bypass Scheme i.e. to scroll through the list of registered (enrolled) sensors to
your PowerMaster system and to Bypass (deactivate) faulty or disturbed sensors (either READY or NOT-
READY) or to Clear (reactivate) BYPASSED zones (sensors).
Once you have set a Bypass Scheme you can use the following 3 options:
> To quickly review the bypassed zones – refer to section B.2.
> To quickly clear a bypassed zone i.e. to reactivate the bypassed zone – refer to section B.1.
> To repeat (recall) the last used zone bypassing scheme – refer to section B.3.
Note: For UL Listed Product, zone bypassing must be conducted on an individual basis each time the system is
armed.
1. Zones will be bypassed throughout one disarm-arm period only. Disarming the system after arming will
suspend the entire bypassing scheme but you can recall and reuse it as described in section B.3.
2. Fire zones cannot be bypassed.
3. Carefully read the section titled "Additional Information" according to the indicated references
1
etc –
see table at end of section B.3.
REMEMBER – ZONE BYPASSING COMPROMISES SECURITY!
A. To Bypass a Zone
Enter the [USER SETTINGS] menu
1
, select the [SET ZONE BYPASS]
2
option and press .
The first zone, Z01, is displayed.