APPENDICES
58 D-303223 PowerMaster-10/30 G2 User's Guide
-4°F to 140°F (-20°C to 60°C)
-4°F to 140°F (-20°C to 60°C)
93% relative humidity, @ 30°C (86°F)
93% relative humidity, @ 30°C (86°F)
196 x 180 x 55 mm (7-5/8 x 7 x 2 in.)
266 x 201 x 63 mm (10-7/16 x 7-7/8 x 2-1/2 in.)
658g (23 Oz) (with battery)
1.44Kg (3.2 pounds) (with battery)
E6. Peripherals and Accessory Devices
GSM/GPRS, IP (future use)
GSM/GPRS, IP (future use)
Additional
wireless devices
30 detectors, 8 keyfobs, 8 keypads, 4 sirens,
4 repeaters, 8 proximity tags
64 detectors, 32 keyfobs, 32 keypads, 8
sirens, 4 repeaters , 32 proximity tags
Wireless Devices
and peripherals
Magnetic Contact: MC-302 PG2, MC-302E
PG2
Motion Detectors: Next PG2; Next K9 PG2,
TOWER-20 PG2, TOWER-32AM PG2 (not UL
listed), TOWER-32AM K9 PG2 (not UL listed),
TOWER-30AM PG2, TOWER-30AM K9 PG2,
CLIP PG2 (not UL listed)
PIR Camera Detectors: Next CAM PG2;
Next CAM-K9 PG2
Smoke Detector: SMD-426 PG2, SMD-427
PG2
GSM Module: GSM-350 PG2 (optional)
Keyfob: KF-234 PG2, KF-235 PG2 (not UL
listed)
Keypad: KP-140 PG2/KP-141 PG2 (with
proximity tag), KP-160 PG2
Indoor Siren: SR-720 PG2
Outdoor Siren: SR-730 PG2
Repeater: RP-600 PG2
Gas: GSD-441 PG2 (not UL listed), GSD-442
PG2
Glass-break: GB-501 PG2 (not UL listed)
Temperature: TMD-560 PG2 (not UL listed)
Flood: FLD-550 PG2 (not UL listed)
Shock: SD-304 PG2 (not UL listed)
Note: UL requires that when using remote
smoke/CO detectors and repeaters, each
detector must be within range (STRONG) of 2
repeaters at all times (for path redundancy –
UL 985).
Magnetic Contact: MC-302 PG2, MC-302E
PG2
Motion Detectors: Next PG2; Next K9 PG2,
TOWER-20 PG2, TOWER-32AM PG2 (not UL
listed), TOWER-32AM K9 PG2 (not UL listed),
TOWER-30AM PG2, TOWER-30AM K9 PG2,
CLIP PG2 (not UL listed)
PIR Camera Detectors: Next CAM PG2;
Next CAM-K9 PG2
Smoke Detector: SMD-426 PG2, SMD-427
PG2
GSM Module: GSM-350 PG2 (optional)
Keyfob: KF-234 PG2, KF-235 PG2 (not UL
listed)
Keypad: KP-140 PG2/KP-141 PG2 (with
proximity tag), KP-160 PG2
Indoor Siren: SR-720 PG2
Outdoor Siren: SR-730 PG2
Repeater: RP-600 PG2
Gas: GSD-441 PG2 (not UL listed), GSD-442
PG2
Glass-break: GB-501 PG2 (not UL listed)
Temperature: TMD-560 PG2 (not UL listed)
Flood: FLD-550 PG2 (not UL listed)
Shock: SD-304 PG2 (not UL listed)
Note: UL requires that when using remote
smoke/CO detectors and repeaters, each
detector must be within range (STRONG) of 2
repeaters at all times (for path redundancy –
UL 985).
APPENDIX F. COMPLIANCE WITH STANDARDS
Compliance Statement
Hereby, Visonic Group declares that the PowerG series of central units and accessories are designed to comply with:
U.S. Standards: (FCC) CFR 47 part 15 and part 68, UL 1023 and UL 985
Canada Standards: RSS 210
European CE Standards
The PowerMaster complies with the RTTE requirements - Directive 1999/5/EC of the European Parliament and of the Council of 9
March 1999.
According to the European standard EN50131-1 and EN 50131-3, the PowerMaster security grading is 2 - "low to medium risk" and
environmental classification is II – "indoor general" and the power supply type is A. EN 50131-6, and ATS4 according to EN 50136.
GSM standards:
Europe: Complies with CE standards 3GPP TS 51.010-1, EN 301 511, EN301489-7
USA: CFR 47 Part 22 (GSM850) and Part 24 (GSM 1900).
Telefication:
PowerMaster-30 G2 is certified by the Dutch testing and certification body Telefication BV to the following standards :
EN 50131-3, EN 50131-6, EN 50131-5-3, EN 50130-4, and EN 50130-5.
Telefication BV has certified only the 868 MHz variant of this product.
Security Grade: