REVIEWING TROUBLES AND ALARM MEMORY
D-303223 PowerMaster-10 / PowerMaster-30 User's Guide 23
Clearing the Memory Indication
To clear the ‘Memory’ indication you must first review the cause of alarm as described above. Once you return
to the ‘Ready’ screen simply press Away
and enter the code if requested, then press Disarm
followed by the code. The memory message will now clear. Otherwise the memory indication and content will be
cleared upon the next arming of the system.
Troubles
A. Indication of Trouble condition
If the system detected a trouble condition in any of the enrolled devices, the TROUBLE indicator illuminates, 3
beeps are sounded once per minute and a flashing TRBL message is displayed, as follows.
READY HH:MM
(alternating)
READY TRBL
or, if the system is not ready for arming -
NOT READY HH:MM
(alternating)
NOT READY TRBL
B. Displaying Trouble Information
All trouble messages need to be reviewed and corrected as described below:
EXAMPLE: The kitchen device - zone No. 9 - has reported a low battery – the living room device zone No. 15 -
has been inactive, and an attempt to communicate a message to your telephone has failed. However, these
troubles do not prevent the system from being “ready to arm”.
To review the source of the current troubles one by one, click the button repeatedly as shown below:
PRESS RESULTING DISPLAY
POWERMASTER-10
∗
Z09 LOW BATTERY
(alternating)
Z09 CONTACT
(alternating)
KITCHEN
Z15 MISSING
(alternating)
Z15 MOTION SENS.
LIVING ROOM
∗
When working from the PowerMaster-30 control panel, the display will read "PowerMaster-30".